Step 1: Unboxing: 

- Remove the lid, electrodes, and adapter from the reservoir

- Slowly lift the lid off the reservoir with a twisting motion

- Remove the electrodes and adapter from the reservoir

- Wash the reservoir and silver rods and rinse thoroughly  

Step 2: Adding distilled water:

- Fill with distilled water to 3/4 inch below the top of the reservoir

- Do not overfill.  The water level should appear about halfway between the top of the  silicone boot and the bottom of the lid (when fully seated)

Step 3: Inserting the pure silver electrodes:

- Hold the electrodes at the base and carefully insert them into the 2 holes located at the bottom of the lid.  Using a twisting motion, make sure they are fully seated and secure.  

- Ensure the electrodes are parallel to one another.  They can be straightened by    gently applying bending pressure at the tips.

Step 4: Sealing the lid onto the reservoir:

- Carefully align the lid over the top of the reservoir and slowly lower down until the electrodes are submerged.  Press the lid down firmly with a slight twisting motion until it is fully seated.

Step 5: Connecting power to the CS-PRO

-Plug in the 24V power supply into any AC outlet (110v - 240v).  Use a simple inexpensive plug adaptor outside of the US where required.   A green LED will light up on the adaptor indicating AC power. 

-Insert the barrel jack into the small hole at the back of the generator lid.  It will briefly flash blue, green and red with a short vibration indicating you are ready to start a brew. 

-To reset and start a new brew, unplug the wall adapter and plug it back in.  While this can be done quickly by removing the barrel jack and reinserting it on the back of the lid, it is not recommended in order to save wear and tear on the jack.


Step 6: Select desired PPM concentration 

- Press the power button on the lid to select the desired PPM concentration:
- Short press (blue light) for 10 PPM.  Typically 40 to 90 minutes until auto shutoff
- Long press (green light) for 20 PPM.  Typically 90 to 120 minutes until auto shutoff.  These brew times depend on water quality and may take as long as 2 hours and 4 hours respectively With ultra Pure 0 PPM distilled water.  The majority of distilled water brands measure approximately 1 PPM to 2 PPM which will effectively reduce the brew times.
- Upon beginning a brew, the rods will initially vibrate for 5 minutes to help get the electrolysis process started, then for 10 seconds on and 10 seconds off until auto shutoff.

Step 7: Toggle vibrational stirring off and on (silent mode).

- For absolute silent operation, double tap the button to toggle the vibrational stirring feature on and off.  The LEDs will flash red or green to indicate the vibrational stirring status.  You can toggle the vibrational stirring feature as often as you like during any brew until auto shut-off.

Step 8: Automatic water purity check:

- If the LEDs flash red after pressing the start button, your water has excessive impurities and should be replaced.

- If you want to continue the brewing process with the water at hand, press the start button again to override and continue with the brew cycle. 

Please note: If the unit flashes red once more, it is a safety feature strongly suggesting you should replace the water.  If you still wish to proceed with your brew (not recommended), cycle the power and start the generator with the electrodes outside the water and then secure the lid onto the reservoir.  Water impurity at this level will likely produce a grey cloudy solution.  Using pure distilled water will insure a crystal clear solution of the highest quality colloidal silver hydrosol.

Step 9: Automatic shut-off:

- The unit will automatically shut off within:
- 2 hours (10 PPM)
- 4 hours (20 PPM)
- The brew cycle is complete when the unit shuts off. 

Typical brew cycle times with typical distilled water Is 45 minutes for 10 PPM and 90 minutes for 20 PPM.

Following the above detailed instructions will ensure that your CS-PRO Colloidal Silver Generator will consistently produce high-quality colloidal silver solutions with ultra-small nanoparticle sizes for maximum bioavailability for many years to come.

Step 9: Cleaning after each brew:

- Use a soft-bristled brush and mild dishwashing liquid to lightly scrub the electrodes after each batch. Rinse thoroughly with tap water and dry with a lint-free cloth.  

- Cleaning the reservoir: After every 5-10 batches, wash the reservoir with a soft-bristled brush and mild dishwashing liquid. Rinse thoroughly with tap water and let dry.

 

Special Features:

-The CS-Pro is the only colloidal silver generator available to utilize a vibrational stirring feature, ensuring ultra-small nanoparticle sizes for maximum bioavailability.

- The CS-Pro includes unique even wearing ultra-pure .99999 silver electrodes with inert nylon tips that are replaceable and ensure the highest quality colloidal silver solution. The constant current alternates from one electrode to another every 5 minutes insuring they stay clean and wear evenly.

- The CS Pro has a built-in water quality check that indicates impure water with a red flashing light, ensuring the user is aware of any water quality issues.

Warranty and Support:

- The Preventology CS-Pro comes with a 1-year full warranty and an unconditional 30-day money-back guarantee.

- Contact Preventology customer support at: support@preventology.co with any questions or comments.